Infusion and transfusion heated sets for single use ТU BY 600012098.018-2008. Infusion, transfusion heated sets are used for injection to the patient of medical solutions, blood and its components out of glass and polymeric fluid containers using device of Ampir type or other device with the same specifications for heating of blood, blood substitutes and solutions for fluid therapy.
Infusion and transfusion heated sets for single use ТU BY 600012098.018-2008. Infusion, transfusion heated sets are used for injection to the patient of medical solutions, blood and its components out of glass and polymeric fluid containers using device of Ampir type or other device with the same specifications for heating of blood, blood substitutes and solutions for fluid therapy.
Characteristic Features
Sets are easy-to-use, are quick to install and to fill.
PRP - heated infusion system for transfusion of solutions.
PKP - a transfusion system for transfusion of blood and its components, heated blood substitutes.
UPS Universal heated sets
Basic elements of sets are a tube and a drip chamber made of medical polyvinyl chloride free of phthalates (DEHP / DOP Free). This material is produced at the enterprise with the use of innovative European materials approved in medical practice.
Operational Performance
- Heated sets can be used with any devices designed for heating of transfusion remedia and solutions;
- Design of polymeric needle makes it possible to connect the set both to firm glass/polymeric containers and to soft polymeric containers. Sharp needle tip could easily pass through either a rubber cork of a bottle or a nipple of a polymeric container with infusion agents providing full discharge of the container;
- Air channel of the polymeric needle is equipped with hydrophobic membrane, sponginess of which is of high performance for transfusion speed; the way of air passing to the container is bacterium-free;
- Semi-flexible transparent drip chamber helps to watch the process of dropping;
- Design of a dropping element provides appearance of 20 drops from (1,0±0,1) ml of the distilled water at a flow speed of (50±5) drops per minute;
- Conic filter, fixed in the chamber of a PKP dropping set, provides elimination of microparticles with a size of more than 175 micron with a filtration coefficient not less than 80% at transfusion of at least 1 l of preserved blood with a 10 – 14 days storage period;
- Filter for solutions, fixed in the drip chamber of PRP set, meets the requirements of the international standard ISO 8536. Filter mesh size is 15 µm, and is considered optimal for supporting the sufficient speed of solution infusion and also for safe filtration of the injected solutions from foreign matters;
- Roller clamp helps to administer solutions with a definite speed starting from a drop infusion to a stream infusion, choosing the most applicable one for the patient;
- Transparent tube wall allows to eliminate possibility of air inclusions entry into a venous bed of the patient;
- Flash ball is intended for additional injections. Self-sealing of the flash ball complies with the requirements of GOST 25047-87 and allows to administer up to 6 injections without loss of sealability. The flash ball is made of antiallergenic synthetic polysopren;
- Luer connector is adapted for injection needles, peripheral and central venous catheters, other medical products with the same port;
- Sharp angle, double sharpening and thin wall provide painless and less traumatic insert of injection needle;
- Individual package contains sealed parcel made of thermoformed composite film and gas-permeable paper with the information relating to the product on it;
- Sterilized by using of ethylene oxide in sterilization chambers.
| Set designation | Set length, mm |
| PKP-01 | 2650 |
| PKP-02 | 2650 |
| PRP-01 | 2650 |
| PRP-02 | 2650 |
| PRP-02 | 2650 |
| UPS-01 | 2500 |
| UPS-02 |
3500 |
At the request of the customer, it is possible to manufacture systems with other connectors, tube lengths and clamps.
|
Correspondence
|
20 drops are equal to 1.0 ml of the distilled water at a flow speed of 50 drops per minute. |
|
Hydrophobic air filter pore size
|
1 µm |
|
Infinitely variable fluid flow rate
|
Smooth adjustment of transfusion speed |
|
The diameter of the injection needle "Luer"
|
0.8 or 1.2 mm (under the customer’s order) |
|
Packing material
|
a parcel made of thermoformed film and gas-permeable paper |
|
Sterility
|
Sterile, pyrogen-free, non-toxic |
|
PRP - filter with mesh size
|
15-to-50 µm mesh size (under the customer’s order) |